By submitting a comment, you are declaring that you agree with these rules:. Computer equipment. Service Manual. Contents About this manual Comments No comments yet. Be the first! Add Comment. Notify me of new comments via email. BIOS and device driver fixes are customer-installable. The BIOS and device drivers. Advise customers to contact the PC Company HelpCenter at if they need assistance in obtaining or installing any diskette fixes.
Make sure that all diskette fixes are installed before replacing any FRUs listed in this manual. Use the following strategy to prevent unnecessary FRU replacement and service expense:. If you are instructed to replace either the processor board or the system board, and replacing one of them does not correct the problem, reinstall that board, and then replace the other one. Before replacing the adapter or device, remove the FRUs, one by one, to see if the symptoms change.
Replace only the FRU that changed the symptoms. Attention: The setup configuration on the computer you are servicing may have been customized. Running Automatic Configuration may alter the settings. Note the current configuration settings using the View Configuration option ; then, when service has been completed, verify that those settings remain in effect. Attention: The drive startup sequence in the computer you are servicing may have been changed.
Be extremely careful during write operations such as copying, saving, or formatting. If you select an incorrect drive, data or programs can be overwritten.
Use the error codes displayed on the screen to diagnose failures. If more than one error code is displayed, begin the diagnosis with the first error code. Whatever causes the first error code may also cause false error codes. If no error code is displayed, see if the error symptom is listed in the Symptom-to-FRU Index for the computer you are servicing. The compatibility of each of the drives with the diskettes for it is as follows:.
In this manual, safety notices appear in English with a page number reference to the appropriate multi-lingual, translated safety notice found in this section. The following safety notices are provided in English, French, German, Italian, and Spanish languages.
Before the computer is powered-on after FRU replacement, make sure all screws, springs, and other small parts are in place and are not left loose inside the computer. Verify this by shaking the computer and listening for rattling sounds.
Metallic parts or metal flakes can cause electrical shorts. Some standby batteries contain a small amount of nickel and cadmium.
Do not disassemble a standby battery, recharge it, throw it into fire or water, or short-circuit it. Dispose of the battery as required by local ordinances or regulations.
Use only the battery in the appropriate parts listing. Use of an incorrect battery can result in ignition or explosion of the battery. Certaines batteries de secours contiennent du nickel et du cadmium. Ne les mettez pas en court-circuit. Die Bereitschaftsbatterie, die sich unter dem Diskettenlaufwerk befindet, kann geringe Mengen Nickel und Cadmium enthalten. Sie darf nicht zerlegt, wiederaufgeladen, kurzgeschlossen, oder Feuer oder Wasser ausgesetzt werden.
No las desmonte, ni recargue, ni las eche al fuego o al agua ni las cortocircuite. The battery pack contains small amounts of nickel. Do not disassemble it, throw it into fire or water, or short-circuit it. Dispose of the battery pack as required by local ordinances or regulations. Use only the battery in the appropriate parts listing when replacing the battery pack.
La batterie contient du nickel. Ne la mettez pas en courtcircuit. Akkus enthalten geringe Mengen von Nickel. Bei der Entsorgung die. The lithium battery can cause a fire, an explosion, or a severe burn. Mettez la pile au rebut. Die Systembatterie ist eine Lithiumbatterie. Auch darf ihr Inhalt nicht mit Wasser in Verbindung gebracht oder der zur richtigen Polung angebrachte Verbindungsstecker entfernt werden. La batteria di supporto e una batteria al litio e puo incendiarsi, esplodere o procurare gravi ustioni.
Evitare di ricaricarla, smontarne il connettore polarizzato, smontarla, riscaldarla ad una temperatura superiore ai gradi centigradi, incendiarla o gettarla in acqua. If the LCD breaks and the fluid from inside the LCD gets into your eyes or on your hands, immediately wash the affected areas with water for at least 15 minutes. Seek medical care if any symptoms from the fluid are present after washing.
To avoid shock, do not remove the plastic cover that protects the lower part of the inverter card. Per evitare scosse elettriche, non rimuovere la copertura in plastica che avvolge la parte inferiore della scheda invertitore. Though the main batteries have low voltage, a shorted or grounded battery can produce enough current to burn personnel or combustible materials.
Before removing any FRU, power off the computer, unplug all power cords from electrical outlets, remove the battery pack, and then disconnect any interconnecting cables. Prima di rimuovere qualsiasi FRU, spegnere il sistema, scollegare dalle prese elettriche tutti i cavi di alimentazione, rimuovere la batteria e poi scollegare i cavi di interconnessione. The following section contains the safety information that you need to be familiar with before servicing an IBM mobile computer.
Ensure you can stand safely without slipping. Distribute the weight of the object equally between your feet. Use a slow lifting force.
Never move suddenly or twist when you attempt to lift. Lift by standing or by pushing up with your leg muscles; this action removes the strain from the muscles in your back. Do not attempt to lift any objects that weigh more than 16 kg 35 lb or objects that you think are too heavy for you. Make sure that your sleeves are fastened or rolled up above your elbows. If your hair is long, fasten it. Attention: Metal objects are good electrical conductors.
Replace any safety device that is worn or defective. Use only approved tools and test equipment. Some hand tools have handles covered with a soft material that does not insulate you when working with live electrical currents.
Many customers have, near their equipment, rubber floor mats that contain small conductive fibers to decrease electrostatic discharges.
Do not use this type of mat to protect yourself from electrical shock. If an electrical accident occurs, you can then operate the switch or unplug the power cord quickly. If you cannot unplug it, ask the customer to power-off the wall box that supplies power to the machine and to lock the wall box in the off position. Attention: Another person must be there to switch off the power, if necessary.
Attention: An electrical shock can occur only when there is a complete circuit. By observing the above rule, you may prevent a current from passing through your body. Observe the special safety precautions when you work with very high voltages; these instructions are in the safety sections of maintenance information.
Use extreme care when measuring high voltages. First, check that it has been powered off. Examples of these hazards are moist floors, nongrounded power extension cables, power surges, and missing safety grounds.
The surface is conductive; such touching can cause personal injury and machine damage. The purpose of this inspection guide is to assist you in identifying potentially unsafe conditions. As each machine was designed and built, required safety items were installed to protect users and service personnel from injury.
This guide addresses only those items. You should use good judgment to identify potential safety hazards due to attachment of non-IBM features or options not covered by this inspection guide. If any unsafe conditions are present, you must determine how serious the apparent hazard could be and whether you can continue without first correcting the problem. Safety information v Mechanical hazards, such as loose or missing hardware.
To determine whether there are any potentially unsafe conditions, use the following checklist at the beginning of every service task. Begin the checks with the power off, and the power cord disconnected. Check exterior covers for damage loose, broken, or sharp edges. Power-off the computer. Disconnect the power cord. Check the power cord for:. A third-wire ground connector in good condition.
Use a meter to measure third-wire ground continuity for 0. The power cord should be the type specified in the parts list. Insulation must not be frayed or worn.
Check for any obvious non-IBM alterations. Use good judgment as to the safety of any non-IBM alterations. Check inside the unit for any obvious unsafe conditions, such as metal filings, contamination, water or other liquids, or signs of fire or smoke damage.
Check for worn, frayed, or pinched cables. Check that the power-supply cover fasteners screws or rivets have not been removed or tampered with. Any computer part containing transistors or integrated circuits ICs should be considered sensitive to electrostatic discharge ESD.
ESD damage can occur when there is a difference in charge between objects. Protect against ESD damage by equalizing the charge so that the machine, the part, the work mat, and the person handling the part are all at the same charge. Use product-specific ESD procedures when they exceed the requirements noted here. Most clothing is insulative and retains a charge even when you are wearing a wrist strap.
The mat is especially useful when handling ESD-sensitive devices. The use of a grounding system is desirable but not required to protect against ESD damage. You can use coax or connector-outside shells on these systems. Electrical grounding of the computer is required for operator safety and correct system function. Proper grounding of the electrical outlet can be verified by a certified electrician. They are also sold separately as options. The drive is certified in the U.
Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure. There are no serviceable parts inside those drives. Do not open. Note the following:. Emits visible and invisible laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam.
Rayonnement laser si carter ouvert. Some descriptions might not apply to your particular computer. Drives in the computer that you are servicing sequence might have been altered. If you select an incorrect drive, data or programs might be overwritten.
Single failures can occur for a variety of reasons that have nothing to do with a hardware defect, such as cosmic radiation, electrostatic discharge, or software errors. Consider replacing a FRU only when a problem recurs.
If you suspect that a FRU is defective, clear the error log and run the test again. If the error does not recur, do not replace the FRU. When you do return a FRU, you must include the following information in the parts exchange form or parts return form that you attach to it:. During the warranty period, the customer may be responsible for repair costs if the computer damage was caused by misuse, accident, modification, unsuitable physical or operating environment, or improper maintenance by the customer.
The following list provides some common items that are not covered under warranty and some symptoms that might indicate that the system was subjected to stress beyond normal use.
Before checking problems with the computer, determine whether the damage is covered under the warranty by referring to the following:. The following symptoms might indicate damage caused by nonwarranted activities:.
If the data on a hard-disk drive is damaged or accidentally erased, you can restore the software that was shipped with the computer.
This software includes the pre-installed operating system, applications, and device drivers. To restore the pre-installed software, you can use either the Product Recovery program or a Recovery CD. The Product Recovery program is in the Service Partition, a section of the hard-disk drive that is not displayed by Windows Explorer.
Use the Recovery CD if it was provided with the computer. To use the Product Recovery program to restore the pre-installed software, do the following:. Save all files and shut down the desktop. Turn on the computer. Press F11 quickly; this message is displayed for only a few seconds. Note: If this message does not appear, you can use a Recovery Repair diskette to get access to the Product Recovery program. From the list displayed on the screen, select the operating system you want to recover.
Select the recovery options you want, and follow the instructions on the screen. To create the Service Partition and install the preloaded system from the Recovery CD, do the following:.
Boot with the Recovery CD and the boot diskette if required. Note: If the hard-disk drive contains any partitions, you do not receive this message ; go to step 1.
Enter Y. The Service Partition is created and loaded with the Product Recovery program files. Note: If you do not want to create the Service Partition, press N key, and then go to step 8.
At next window, press Enter to continue. The system automatically reboots during this process. You may be prompted to change CDs. Continue to step 6 to install preloaded system. Product Recovery program Reinstall the Product Recovery Program? If you get a message asking which operating system to install, highlight the proper operating system and press Enter.
Press Enter to select. Enter the Y at each of the next three windows. Follow the prompts to complete Recovery. If the prompt needed for access to the Product Recovery program does not appear, you can recover it by use of the. Recovery Repair diskette. Make a Recovery Repair diskette and save it for future use. To make a Recovery Repair diskette:. Shut down and turn off the computer.
Attach the external diskette drive to the computer. At the prompt, press F The option to press F11 appears for only a few seconds. You must press F11 quickly. The Product Recovery program main menu appears. If you are using Windows Professional, you are prompted to select an operating system. This menu does not appear for Windows 98 SE.
From the main menu, select System Utilities. Press Enter. Select Create a Recovery Repair diskette. Follow the on-screen instructions. When the process is completed, label the diskette as the Recovery Repair diskette and save it for future use. Insert the Recovery Repair diskette into the drive; then turn on the computer. Should the hard-disk drive need to be replaced, you must order a Recovery CD with the hard-disk drive so that you can recover the new hard-disk drive with the pre-installed software when it arrives.
If any of these passwords have been set, a prompt for it appears on the screen whenever the computer is turned on. The computer does not start until the password is entered.
A power-on password POP protects the system from being powered on by an unauthorized person. The password must be entered before an operating system can be booted. The system administrator then provides the user HDP to the system user. It it has, it can be used for access to the hard-disk drive. The hard-disk drive can be replaced for a scheduled fee. If the SVP has been forgotten and cannot be made available to the servicer, there is no service procedure to reset the password.
The systemboard must be replaced for a scheduled fee. Remove the backup battery. Turn on the computer and wait until the POST ends. After the POST ends, the password prompt does not appear.